  柴油发电机组必须由熟悉机组结构、掌握安全操作规程的人员上岗操作。新的或刚经过大修的柴油机组要按规定经过60小时的磨合运转,并做好必要的保养。
  对于新的或长期不用的发电机在投入正常运行之前,必须经过严格的检查,主要检查绕组绝缘情况、接线情况等,如有不符,进行必要处理。
  柴油机起动后应慢慢提高转速,经检查确认一切完好的前提下,可进行低速到额定转速的空载运行。空载运行时,着重检查机油压力,有无异响,励磁电流、三相电压变化等,如有异常情况——应立即停机检查。查明情况后,再行起动。如一切正常,即可投入正常运行。操作人员要严密监视控制屏上的仪表的变化情况,是否在许可范围,并作相应的调整。
  操作时,操作人员应与带电设备保持安全距离,并穿戴好劳动防护装备。倒闸操作要注意先后次序,如停电应先断开各分支开关,然后再断开总开关,再进行四极双投刀闸切换位置。送电时,顺序相反进行。正常停机应先卸掉部分负载,再断总开关,最后关柴油机,不允许不拉断总开关,随柴油机熄火而自行停电。停机后对机组作常规性检查,并记录运行情况(工作日记)。
  万一发生有人触电,应迅速切断电源开关,或用绝缘器具迅速使电源断掉或脱离电源。然后进行抢救,并请医生来现场抢救。万一遇有电气设备水灾时,应立即将有关电源切断,并报告当地供电所,然后进行救火。对带电设备救火应使用干式灭火器、二氧化碳灭火器等,不准用水。